Feature description
Fully automatic computer control, no need for dedicated personnel to operate, can automatically work within the set time period, save energy, reduce heat loss, can continuously supply hot water, and automatically sense water replenishment.
Inserting smoke blocking fins into the furnace flue tube enhances heat transfer, reduces exhaust gas temperature, and achieves a thermal efficiency of over 94%.
Automatic control functions such as digital temperature display, temperature control, and over temperature protection.
Adopting well-known brand combustion engines with intelligent control, equipped with automatic blowing, electronic automatic ignition, automatic combustion, automatic proportional adjustment of air and oil (gas), and flameout protection devices.
The water inlet is controlled by a reliable electromagnetic valve, and automatically insulated after shutdown.
The inner liner has undergone special treatment, resulting in 100% pure water quality. Color board outsourcing, beautiful and elegant, not easily corroded.

Parameter
|
Model |
Rated evaporation rate(MW) |
Rated Working Pressure (MPa) |
Inlet/outlet water temperature (℃) |
Thermal Efficiency (%) |
Natural gas consumption(m³) |
Shipping Weight(t) |
|
CLHS0.06-100/10-Y/Q |
0.06 |
atmospheric pressure |
100/10 |
>94 |
6.6 |
0.209 |
|
CLHS0.08-100/10-Y/Q |
0.08 |
atmospheric pressure |
100/10 |
>94 |
8.86 |
0.263 |
|
CLHS0.12-100/10-Y/Q |
0.12 |
atmospheric pressure |
100/10 |
>94 |
13.2 |
0.290 |
|
CLHS0.175-100/10-Y/Q |
0.175 |
atmospheric pressure |
100/10 |
>94 |
19.4 |
0.365 |
|
CLHS0.24-100/10-Y/Q |
0.24 |
atmospheric pressure |
100/10 |
>94 |
26.6 |
0.481 |
|
CLHS0.35-100/10-Y/Q |
0.35 |
atmospheric pressure |
100/10 |
>94 |
38.8 |
0.70 |
|
CLHS0.48-100/10-Y/Q |
0.48 |
atmospheric pressure |
100/10 |
>94 |
54.2 |
0.90 |
|
CLHS0.58-100/10-Y/Q |
0.58 |
atmospheric pressure |
100/10 |
>94 |
56.3 |
1.122 |
|
CLHS0.7-100/10-Y/Q |
0.7 |
atmospheric pressure |
100/10 |
>94 |
62.7 |
1.35 |
(*For reference only)
Consumption of light oil combustion
|
Model |
light oil(Kg/h) |
|
CLHS0.06-100/10-Y/Q |
5.6 |
|
CLHS0.08-100/10-Y/Q |
7.5 |
|
CLHS0.12-100/10-Y/Q |
10.7 |
|
CLHS0.175-100/10-Y/Q |
16 |
|
CLHS0.24-100/10-Y/Q |
21.4 |
|
CLHS0.35-100/10-Y/Q |
32.7 |
|
CLHS0.48-100/10-Y/Q |
41.7 |
|
CLHS0.58-100/10-Y/Q |
56.3 |
|
CLHS0.7-100/10-Y/Q |
62.7 |
When you encounter a problem
1. Contact us first: We will diagnose the problem remotely through phone, video, and other means, and most minor issues can be resolved through guidance.
2. If parts need to be replaced: If we determine that it is a quality issue with the equipment itself, we will send you new parts free of charge (usually through international express delivery) and guide you or local technicians to replace them.
Hot Tags: vertical natural pressure water boiler, China vertical natural pressure water boiler manufacturers, suppliers, factory, Low Nitrogen Condensing Vacuum Hot Water Boiler, Low nitrogen Natural Pressure Gas and Oil Hot Water Boiler, vacuum hot water boiler, Vertical Natural Pressure Water Boiler, Water Tube Low NOx Condensing Vacuum Hot Water Boiler