| 1. Applicable medium | liquefied natural gas (LNG) |
| 2. Dimensions (length x width x height) | (4000 * 2250 * 2540mm) |
| 3. Design head | 220-28Dm |
| 4. Design speed | 5800r/min |
| 5. Design flow rate | 360L/min |
| 6. EAG heater | 150Nm/h |
| 7. Turbocharger | 200Nm ² m |
| 8. Pressure test before/after pressure pump | 1.84/2.88Mpa |
| 9. Air tightness test pressure before/after pump | 1.6/2.5Mpa |
| 10. Design pressure pump before/after | 1.6/2.5Mpa |
| 11. Working pressure before/after the pump | 1.0/1.6Mpa |
| 12. Design temperature | -196 ℃ |
| 13. Working temperature | -162 ° C |
| 14. Pipeline flange common pressure | 4.0Mpa |
| 15. Motor power | 11KW/15KW |
| 16. Power supply | three-phase 380V50HZ |
| 17. Weight | Approximately 3000kg |
| 18. LNG low-temperature pump pry (single pump) supports the operation of 2 single gun liquid dispensers |
Main advantages
|
Lowest initial investment cost: |
Only one main pump and related pipeline valves are configured, and the equipment procurement cost is significantly lower than that of a double pump pry, making it the preferred choice for the most cost sensitive construction project. |
|
Simple structure and compact footprint: |
The number of equipment components and process pipelines is small, the size of the pry body is small, and the footprint is smaller, making it easy to arrange in stations with limited space, especially in pry stations. |
|
Easy operation and maintenance, with few fault points: |
A single system means lower workload and cost for daily inspections and maintenance. The electrical control logic is also relatively simple, reducing the technical threshold and risk of misoperation for operators. |
|
Relatively low energy consumption: |
Only one pump is running, which results in lower total energy consumption compared to a dual pump system (which may require pre cooling or circulation of the backup pump). |
Hot Tags: single pump LNG cryogenic pump skid, China single pump LNG cryogenic pump skid manufacturers, suppliers, factory, L CNG Plunger Pump Skid, lng cryogenic pump skid, Simple LNG Cryogenic Pump Skid, Containerized LNG Cryogenic Pump Skid, Dual Pump LNG Cryogenic Pump Skid, Single Pump LNG Cryogenic Pump Skid