Working principle
The electric pressurized hot water boiler is a "direct heating" pressurized equipment
1.Electrothermal conversion: After connecting to a high-voltage power source, the current passes through an electric heating tube immersed in water or directly through a body of water, converting electrical energy directly into thermal energy.
2.Pressure cycle: The heated water experiences an increase in pressure within a sealed boiler cylinder. The system circulation pump forcibly delivers high-temperature and high-pressure hot water from the boiler to the heating or process end, and the cooled return water is pumped back to the boiler for reheating, forming a closed pressure circulation system.
3.Automatic control: By using temperature and pressure sensors and a PLC controller, the start stop or power of the heating group is automatically adjusted to maintain a stable outlet temperature and system pressure.

Parameter
|
Model |
Rated evaporation rate(MW) |
Rated Working Pressure (MPa) |
Inlet/outlet water temperature (℃) |
Thermal Efficiency (%) |
Single heating tube power (KW) |
Number of heating tubes (group) |
Shipping Weight(t) |
|
WDR0.35-1.0/95/70 |
0.35 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
30 |
12 |
1.526 |
|
WDR0.54-1.0/95/70 |
0.54 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
10 |
1.632 |
|
WDR0.7-1.0/95/70 |
0.7 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
13 |
2.179 |
|
WDR1.05-1.0/95/70 |
1.05 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
18 |
2.687 |
|
WDR1.4-1.0/95/70 |
1.4 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
24 |
3.215 |
|
WDR2.1-1.0/95/70 |
2.1 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
36 |
3.917 |
|
WDR2.8-1.0/95/70 |
2.8 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
48 |
5.445 |
|
WDR4.2-1.0/95/70 |
4.2 |
1.0/1.25/1.6 |
95/70,115/70,130/70 |
>98 |
60 |
71 |
7.122 |
(*For reference only)
Reasons and advantages of "pressure bearing" design
- Reason 1: Adapt to modern closed heating/process systems
- Reason 2: Improve effluent temperature and efficiency
- Reason 3: Compact structure reduces oxygen corrosion
Selling points and market positioning
- The operation process has no combustion, no smoke, no nitrogen oxides, and no carbon dioxide emissions, making it a "zero pollution" heat source.
- The conversion efficiency from electrical energy to thermal energy is nearly 99%, far exceeding any fuel boiler. Fast startup and responsive.
- No flame, no fuel storage and leakage risk. The equipment body complies with pressure vessel specifications and has complete safety protection.
- The operating noise is extremely low, with only the sound of the fan or water pump, which is superior to all combustion boilers.
- No need for complex auxiliary systems such as chimneys, fuel storage tanks, and oil pump rooms, simple installation, and small footprint.
Hot Tags: electric pressure hot water boiler, China electric pressure hot water boiler manufacturers, suppliers, factory, hot water boiler system, lng oil and gas, lng in gas, lng cryogenic, lng products, water hot boiler